Proper curing—maintaining adequate moisture and temperature in freshly-placed concrete—is essential to achieving pavement strength and durability. When concrete dries out prematurely, cement cannot fully hydrate, leading to lower strength and increased permeability.
The factor predominantly controlling mixture performance is the water-to-cementitious-materials ratio (w/cm) at the time of setting. Increasing the w/cm may improve workability, but strength, permeability, and durability are compromised. For concrete exposed to freezing and thawing, typical ratios fall between 0.40 and 0.45. At these ratios, an effective curing period is generally three to seven days, depending on the mixture design, temperature, and exposure.
With a w/cm ratio below about 0.40, the risk increases that there will not be enough water in the mixture to hydrate all of the cement, leading to so-called self-desiccation. The curing of such mixtures cannot depend solely on sealing in the mixture water already present within the element because this water is insufficient to support complete hydration; therefore, external water will need to be added.
In low w/cm mixtures, crews sometimes add water out of unfounded concern there is not enough to fully hydrate the cement. In higher w/cm mixtures, the typical strategy is to seal the surface to limit evaporation. In both cases, decisions often hinge on the presence or absence of visible water at the surface. This approach can prove less reliable when a cementitious system other than plain portland cement is used.
“Proper curing has always been a best practice, but it takes on even greater importance as we transition to low-embodied-carbon concrete materials. These mixes have been reported to exhibit reduced bleeding compared to traditional portland cement concrete. When crews notice surface dryness and respond by adding water or working in a finishing aid, they introduce a local increase in the w/cm ratio, which weakens that layer and reduces its long-term durability” said Tom Van Dam, principal at Wiss, Janney, Elstner Associates, Inc. (WJE).
The NC2 MAP Brief Curing for Exterior Concrete Slabs details the “how to” of ensuring moisture control and curing in various temperature conditions.